56 documents found in 264ms
# 1
Albert, Francisca
Abstract: This data set includes movies and images of sandbox experiments aiming at understainding the process of subduction erosion at active plate margins (Albert, 2013). Four experiments are documented by means of movies showing the evolution of a strong wedge (sand-sugar mix, “Reference experiment.avi”), a weak wedge (sand only, “F1 experiment.avi”) and two successive phases of a wedge that undergoes subduction erosion by subducting topographic highs (first stage without subducting topography= “HL.1 experiment.avi” and second stage with subducting topography = “HL.2 experiment.avi”). Images of preliminary tests and experiments not considered in Albert (2013) are given in “Appendix A2.2.pdf” (small box experiments) and “Appendix A3.3.pdf” (experiments varying friction and slope).
# 2
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 3
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 4
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 5
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 6
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 7
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 8
KTB, WG Geophysics
Abstract: The magnetic susceptibility is measured by an inductive AC device (BARTINGTON). The sample is placed inside a coil which generates an alternating magnetic field. The applied frequency is 460 Hz (cuttings, 25.4 mm mini cores), 565 Hz (cores) or 1470 Hz (15 mm mini cores) respectively. A shift in the oscillator frequency is a measure for the magnetic susceptibility of the sample. The applied magnetic field strength is 80 A/m (RMS) and appr. 2 times the total earth magnetic field strength in the KTB area (=38 A/m). The measurement field is lower than the field which is necessary for magnetic saturation and allows therefore to measure the initial susceptibility. The used sensors are insensitive to the electrical conductivity of the samples. Except the determination of the temperature dependent susceptibility, all measurements are done under surface conditions (room temperature and atmospheric pressure).
# 9
KTB, WG Geophysics
Abstract: In general, four-electrode devices are used to measure the resistivity on original (unprepared) cores and on mini cores drilled from these original cores. The in-phase and the out-of-phase signal is measured and therefore the complex resistivity is determined. All measurements are performed under surface conditions (room temperature and atmospheric pressure).Four point like electrodes are situated at the core surface along a semicircle in a plane perpendicular to the core axis. The two current electrodes are opposite to each other. The electrodes are in contact to the sample by a porous plastic material soaked with 0.1 molar NaCl solution. Voltage and current is measured by a lock-in-amplifier at 120 Hz frequency. Due to high contact resistances, only the magnitude of complex resistivity is used. By computer controlled rotating of the core and moving of the electrode arrangement along the cores z axis, resistivity as a function of azimuth and length is measured.
# 10
KTB, WG Geophysics
Abstract: In general, four-electrode devices are used to measure the resistivity on original (unprepared) cores and on mini cores drilled from these original cores. The in-phase and the out-of-phase signal is measured and therefore the complex resistivity is determined. All measurements are performed under surface conditions (room temperature and atmospheric pressure). Four point like electrodes are situated at the core surface along a semicircle in a plane perpendicular to the core axis. The two current electrodes are opposite to each other. The electrodes are in contact to the sample by a porous plastic material soaked with 0.1 molar NaCl solution. Voltage and current is measured by a lock-in-amplifier at 120 Hz frequency. Due to high contact resistances, only the magnitude of complex resistivity is used. By computer controlled rotating of the core and moving of the electrode arrangement along the cores z axis, resistivity as a function of azimuth and length is measured.
spinning wheel Loading next page