2024-03-28T20:27:09Zhttp://doidb.wdc-terra.org/oaip/oaioai:doidb.wdc-terra.org:61292023-04-06T13:58:05ZDOIDBDOIDB.GFZ
10.5880/GFZ.b103-15021.1
Reinsch, Thomas
0000-0002-5803-9819
GFZ German Research Center for Geosciences
Blöcher Guido
23468406300
GFZ German Research Center for Geosciences
Kranz, Stefan
GFZ German Research Center for Geosciences
Data From The Groß Schönebeck Research Platform 2011-06-01 - 2013-12-31 (Datasets)
GFZ Data Services
2015
hydraulic testing
thermal water loop
EPOS
geo-energy test beds
Reinsch, Thomas
0000-0002-5803-9819
GFZ German Research Center for Geosciences
Reinsch, Thomas
0000-0002-5803-9819
GFZ German Research Center for Geosciences
Blöcher Guido
23468406300
GFZ German Research Center for Geosciences
Blöcher Guido
23468406300
GFZ German Research Center for Geosciences
Kranz, Stefan
GFZ German Research Center for Geosciences
Kranz, Stefan
GFZ German Research Center for Geosciences
Huenges, Ernst
0000-0002-3632-4619
GFZ German Research Center for Geosciences
Section 4.1 Reservoirtechnologies
GFZ German Research Center for Geosciences
International Centre for Geothermal Research ICGR
GFZ German Research Center for Geosciences
2011-06-01/2013-12-31
en
10.2312/GFZ.b103-15021
10.1016/j.geothermics.2015.07.008
181396214 Bytes
4 Files
application/x-zip-compressed
application/x-zip-compressed
application/x-zip-compressed
application/x-zip-compressed
CC Attribution 4.0 (CC BY 4.0)
This data is documented by the Scientific Technical Report Data 15/02 (http://dx.doi.org/10.2312/GFZ.b103-15021). Both, the data and the report, are supplements to the publication Blöcher et al. (2015), accessible via http://dx.doi.org/10.1016/j.geothermics.2015.07.008.
From 2011-06-01 until 2013-12-31, the measurement and control system at the Groß Schönebeck research platform acquired data from several circulation experiments. Different data values were recorded at a sampling interval of 1 s. Relevant data for understanding and analyzing the hydraulic situation of the system were resampled to a 1 minute interval. From the resampled dataset, additional parameters were derived. Furthermore, if parameters were considered to be essential, but the measurement of these parameters was erroneous, some data were reprocessed. All relevant data and processing steps performed on the data are described within this report. Data described within this report can be accessed via http://dx.doi.org/10.5880/GFZ.b103-15021.1.
The presented data was acquired during different research projects by the staff of the International Centre for Geothermal Research as well as Section 4.1 Reservoirtechnologies at the Helmholtz Centre Potsdam GFZ German Research Centre for Geosciences.
52.90313654663532 13.60109567642212 52.90432724048678 13.602479696273804
Geothermal Research Platform Groß Schönebeck