<?xml version="1.0" encoding="UTF-8" ?><?xml-stylesheet type="text/xsl" href="xsl/oaitohtml.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-16T22:24:30Z</responseDate><request identifier="oai:doidb.wdc-terra.org:172" metadataPrefix="oai_datacite" verb="GetRecord">http://doidb.wdc-terra.org/oaip/oai</request><GetRecord><record><header><identifier>oai:doidb.wdc-terra.org:172</identifier><datestamp>2016-11-25T15:11:37Z</datestamp><setSpec>DOIDB</setSpec><setSpec>DOIDB.SDDB</setSpec></header><metadata><oai_datacite xmlns="http://schema.datacite.org/oai/oai-1.0/" xsi:schemaLocation="http://schema.datacite.org/oai/oai-1.0/ http://schema.datacite.org/oai/oai-1.0/oai.xsd"><isReferenceQuality>false</isReferenceQuality><schemaVersion>3</schemaVersion><datacentreSymbol>DOIDB.SDDB</datacentreSymbol><payload><resource xmlns="http://datacite.org/schema/kernel-3"
          xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
          xsi:schemaLocation="http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd">
   <identifier identifierType="DOI">10.1594/GFZ.SDDB.1084</identifier>
   <creators>
      <creator>
         <creatorName>SAFOD</creatorName>
      </creator>
   </creators>
   <titles>
      <title>SAFOD Main Hole downhole logging data phase 1.2 1556-1744m</title>
   </titles>
   <publisher>Deutsches GeoForschungsZentrum GFZ</publisher>
   <publicationYear>2008</publicationYear>
   <subjects>
      <subject subjectScheme="project">San Andreas Fault-Zone Observatory at Depth</subject>
      <subject subjectScheme="platform">Land based</subject>
      <subject subjectScheme="keyword">Apparent Water Resistivity</subject>
      <subject subjectScheme="keyword">Array Induction Four Foot Conductivity A60</subject>
      <subject subjectScheme="keyword">Array Induction Four Foot Resistivity A10</subject>
      <subject subjectScheme="keyword">Array Induction Four Foot Resistivity A20</subject>
      <subject subjectScheme="keyword">Array Induction Four Foot Resistivity A30</subject>
      <subject subjectScheme="keyword">Array Induction Four Foot Resistivity A60</subject>
      <subject subjectScheme="keyword">Array Induction Four Foot Resistivity A90</subject>
      <subject subjectScheme="keyword">Array Induction Mud Resistivity Fully Calibrated</subject>
      <subject subjectScheme="keyword">Array Induction One Foot Resistivity A10</subject>
      <subject subjectScheme="keyword">Array Induction One Foot Resistivity A20</subject>
      <subject subjectScheme="keyword">Array Induction One Foot Resistivity A30</subject>
      <subject subjectScheme="keyword">Array Induction One Foot Resistivity A60</subject>
      <subject subjectScheme="keyword">Array Induction One Foot Resistivity A90</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Conductivity A60</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Conductivity A90</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Inner Diameter of Invasion</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Outer Diameter of Invasion (D2)</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Resistivity A10</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Resistivity A20</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Resistivity A30</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Resistivity A60</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Resistivity A90</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Rt</subject>
      <subject subjectScheme="keyword">Array Induction Two Foot Rxo</subject>
      <subject subjectScheme="keyword">Backscatter Delta Rho</subject>
      <subject subjectScheme="keyword">Cable Tension</subject>
      <subject subjectScheme="keyword">Cal. Caliper</subject>
      <subject subjectScheme="keyword">calculation</subject>
      <subject subjectScheme="keyword">Cartridge Temperature</subject>
      <subject subjectScheme="keyword">Computed Gamma Ray</subject>
      <subject subjectScheme="keyword">Conductivity logging</subject>
      <subject subjectScheme="keyword">Corrected Far Thermal Counting Rate</subject>
      <subject subjectScheme="keyword">Corrected Near Thermal Counting Rate</subject>
      <subject subjectScheme="keyword">Delta Thermal Neutron Porosity</subject>
      <subject subjectScheme="keyword">Density correction</subject>
      <subject subjectScheme="keyword">Differential Caliper</subject>
      <subject subjectScheme="keyword">dry weight fraction</subject>
      <subject subjectScheme="keyword">DW Anhydrite/Gypsum</subject>
      <subject subjectScheme="keyword">DW Calcium</subject>
      <subject subjectScheme="keyword">DW Carbonate</subject>
      <subject subjectScheme="keyword">DW Clay</subject>
      <subject subjectScheme="keyword">DW Coal</subject>
      <subject subjectScheme="keyword">DW Gadolinium</subject>
      <subject subjectScheme="keyword">DW Iron + 0.14 Aluminum</subject>
      <subject subjectScheme="keyword">DW Pseudo Aluminum</subject>
      <subject subjectScheme="keyword">DW Pyrite</subject>
      <subject subjectScheme="keyword">DW Quartz+Feldspar+Mica (QFM)</subject>
      <subject subjectScheme="keyword">DW Salt</subject>
      <subject subjectScheme="keyword">DW Siderite</subject>
      <subject subjectScheme="keyword">DW Silicon</subject>
      <subject subjectScheme="keyword">DW Sulfur</subject>
      <subject subjectScheme="keyword">DW Titanium</subject>
      <subject subjectScheme="keyword">ECS Temperature</subject>
      <subject subjectScheme="keyword">Elemental Statistical Uncertainty Factor</subject>
      <subject subjectScheme="keyword">Enhanced Thermal Neutron Porosity</subject>
      <subject subjectScheme="keyword">environmentally corrected gamma-ray</subject>
      <subject subjectScheme="keyword">Formation Potassium Concentration</subject>
      <subject subjectScheme="keyword">Formation Thorium Concentration</subject>
      <subject subjectScheme="keyword">Formation Uranium Concentration</subject>
      <subject subjectScheme="keyword">gamma ray</subject>
      <subject subjectScheme="keyword">gamma ray logging</subject>
      <subject subjectScheme="keyword">Generalized Borehole Temperature</subject>
      <subject subjectScheme="keyword">HGNS</subject>
      <subject subjectScheme="keyword">HGNS deviation</subject>
      <subject subjectScheme="keyword">High Resolution Invaded Zone Resistivity</subject>
      <subject subjectScheme="keyword">HILT</subject>
      <subject subjectScheme="keyword">HiRes Enhanced Thermal Neutron Porosity</subject>
      <subject subjectScheme="keyword">HiRes Gamma-Ray</subject>
      <subject subjectScheme="keyword">HiRes Thermal Neutron Porosity</subject>
      <subject subjectScheme="keyword">HNGS</subject>
      <subject subjectScheme="keyword">HRDD</subject>
      <subject subjectScheme="keyword">Matrix Density</subject>
      <subject subjectScheme="keyword">MCFL</subject>
      <subject subjectScheme="keyword">Micro Inverse Resistivity</subject>
      <subject subjectScheme="keyword">Micro Normal Resistivity</subject>
      <subject subjectScheme="keyword">Photoelectric Factor Correction</subject>
      <subject subjectScheme="keyword">Photomultiplier Tube Quality Control</subject>
      <subject subjectScheme="keyword">Porosity CrossPlot</subject>
      <subject subjectScheme="keyword">Resistivity logging</subject>
      <subject subjectScheme="keyword">SP Armor Return</subject>
      <subject subjectScheme="keyword">Spontaneous Potential Shifted</subject>
      <subject subjectScheme="keyword">Standard Gamma Ray</subject>
      <subject subjectScheme="keyword">Standard Resolution Density Porosity</subject>
      <subject subjectScheme="keyword">Standard Resolution Density Standoff</subject>
      <subject subjectScheme="keyword">Standard Resolution Formation Density</subject>
      <subject subjectScheme="keyword">Standard Resolution Formation Photoelectric Factor</subject>
      <subject subjectScheme="keyword">Standard Resolution Invaded Zone Resistivity</subject>
      <subject subjectScheme="keyword">Standard Resolution Resistivity Standoff</subject>
      <subject subjectScheme="keyword">Stuck Tool Indicator, Total</subject>
      <subject subjectScheme="keyword">temperature</subject>
      <subject subjectScheme="keyword">Thermal Neutron Porosity</subject>
      <subject subjectScheme="keyword">Thermal Neutron Porosity (Ratio Method)</subject>
      <subject subjectScheme="sensor">LL3, DIL, DLL</subject>
   </subjects>
   <dates>
      <date dateType="Issued">2008-01-30</date>
   </dates>
   <language>eng</language>
   <resourceType resourceTypeGeneral="Dataset">Dataset</resourceType>
   <relatedIdentifiers>
      <relatedIdentifier relatedIdentifierType="DOI" relationType="IsSupplementTo">10.1016/j.apgeochem.2008.01.012</relatedIdentifier>
   </relatedIdentifiers>
   <sizes>
      <size>99954 DataPoints</size>
   </sizes>
   <formats>
      <format>text/tab-separated-values</format>
   </formats>
   <descriptions>
      <description descriptionType="Abstract">SAFOD is motivated by the need to answer fundamental questions about the physical and chemical processes controlling faulting and earthquake generation within a major plate-bounding fault. SAFOD will drill and instrument an inclined borehole across the San Andreas Fault Zone to a depth of 3.2 km, targeting a repeating microearthquake source. The drill site is located west of the vertical San Andreas Fault on a segment of the fault that moves through a combination of aseismic creep and repeating microearthquakes. It lies at the extreme northern end of the rupture zone of the 1966, Magnitude 6 Parkfield earthquake, the most recent in a series of events that have ruptured the fault five times since 1857. The Parkfield region is the most comprehensively instrumented section of a fault anywhere in the world, and has been the focus of intensive study for the past two decades. This data set contains open hole geophysical wireline logging data from 1556-1744m (rel. to rig floor, 9,45m abv gnd)</description>
   </descriptions>
   <geoLocations>
      <geoLocation>
         <geoLocationBox>35.9712 -120.5513 35.9713 -120.5512</geoLocationBox>
      </geoLocation>
   </geoLocations>
</resource></payload></oai_datacite></metadata></record></GetRecord></OAI-PMH>